CPR B2ca - s1, d1, a1 Fire Alarm Cable
Fire Alarm Cable
Electrical cables designed for applications in automatic fixed systems for detection and signaling of fire alarms, with enhanced reaction-to-fire characteristics in accordance with the Construction Products Regulation (CPR). The cables provide excellent flame retardancy, low smoke emission and reduced flaming droplets, making them suitable for fire alarm and other safety-critical systems.
CPR B2ca - s1, d1, a1 Fire Alarm Cable
Fire Alarm Cable
Electrical cables designed for applications in automatic fixed systems for detection and signaling of fire alarms, with enhanced reaction-to-fire characteristics in accordance with the Construction Products Regulation (CPR). The cables provide excellent flame retardancy, low smoke emission and reduced flaming droplets, making them suitable for fire alarm and other safety-critical systems.
Suitable for automatic fire detection and fire alarm systems, emergency signaling circuits and safety-critical installations in commercial buildings, hospitals, hotels, public buildings, transportation facilities, shopping malls, data centers and other infrastructure projects where enhanced CPR fire-performance requirements apply.
TECHNICAL SPECIFICATIONS EN
| Features | Values | Rules |
| Product Type | CPR B2ca 2-Core Fire Alarm Cable | EN 50575 |
| Conductor | Bare Copper | EN 60228 |
| Conductor Class | Class 5 | EN 60228 |
| Cores | 2 Cores | — |
| Core Colours | Red / Black | — |
| Insulation | LSZH / XLPO | Product Specification |
| Screen | Al/PET Tape | — |
| Drain Wire | Tinned Copper | — |
| Outer Sheath | LSZH | — |
| Sheath Colour | Red, RAL 3000 | — |
| CPR Classification | B2ca-s1a,d1,a1 | EN 13501-6 |
| Flame Spread | ≤ 1.5 m | EN 50399 |
| FIGRA | ≤ 150 W/s | EN 50399 |
| THR₁₂₀₀s | ≤ 15 MJ | EN 50399 |
| Peak HRR | ≤ 30 kW | EN 50399 |
| Smoke Classification | s1a | EN 61034-2 |
| Droplet Classification | d1 | EN 50399 |
| Acidity Classification | a1 | EN 60754-2 |
| Rated Voltage | 100/100 V* | Product Specification |
| Max. Working Temperature | +90 °C* | Product Specification |
| Testing Voltage | 2000 V* | Product Specification |
| Application | Fire Alarm & Fire Detection Systems | — |
VARIANTS
TYPE N° x mm2
2x0.50, 2x0.75, 2x1, 2x1.5, 2x2.5, 2x2.5, 4x0.75, 4x1, 4x1.5, 4x2.5
Suitable for automatic fire detection and fire alarm systems, emergency signaling circuits and safety-critical installations in commercial buildings, hospitals, hotels, public buildings, transportation facilities, shopping malls, data centers and other infrastructure projects where enhanced CPR fire-performance requirements apply.
TECHNICAL SPECIFICATIONS EN
| Features | Values | Rules |
| Product Type | CPR B2ca 2-Core Fire Alarm Cable | EN 50575 |
| Conductor | Bare Copper | EN 60228 |
| Conductor Class | Class 5 | EN 60228 |
| Cores | 2 Cores | — |
| Core Colours | Red / Black | — |
| Insulation | LSZH / XLPO | Product Specification |
| Screen | Al/PET Tape | — |
| Drain Wire | Tinned Copper | — |
| Outer Sheath | LSZH | — |
| Sheath Colour | Red, RAL 3000 | — |
| CPR Classification | B2ca-s1a,d1,a1 | EN 13501-6 |
| Flame Spread | ≤ 1.5 m | EN 50399 |
| FIGRA | ≤ 150 W/s | EN 50399 |
| THR₁₂₀₀s | ≤ 15 MJ | EN 50399 |
| Peak HRR | ≤ 30 kW | EN 50399 |
| Smoke Classification | s1a | EN 61034-2 |
| Droplet Classification | d1 | EN 50399 |
| Acidity Classification | a1 | EN 60754-2 |
| Rated Voltage | 100/100 V* | Product Specification |
| Max. Working Temperature | +90 °C* | Product Specification |
| Testing Voltage | 2000 V* | Product Specification |
| Application | Fire Alarm & Fire Detection Systems | — |
VARIANTS
TYPE N° x mm2
2x0.50, 2x0.75, 2x1, 2x1.5, 2x2.5, 2x2.5, 4x0.75, 4x1, 4x1.5, 4x2.5